Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13670278

- Product Categories
- Electromagnetic vibration t..
- Temperature and humidity ch..
- UV accelerated aging test
- Xenon weathering test chamb..
- Thermal Shock Chambers
- High and low temperature
- Rapid temperature change ch..
- Tensile testing machine
- Simulation Transport Vibrat..
- Friendly Links
Information Name: | Nanjing high and low temperature heat chamber factory outlets |
Published: | 2015-06-02 |
Validity: | 365 |
Specifications: | 225L |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | Nanjing high and low temperature heat chamber factory direct, reliable quality, the price is, a lot of concessions, Dongguan Cowan engaged in the development, production and sales of environmental testing equipment for thirteen years, with mature technology, superb technology and strict quality control, Product sales hit record highs, won many new and old customers praise and recognition. Nanjing high and low temperature heat chamber adapted to electrical and electronic industry, military, plastic, metal, chemical and other industries, such as: electronic parts, auto parts, laptops and other products simulate climatic environmental testing and other related product components at high temperature, low temperature environment storage, transportation, use of adaptive testing, assessment of its performance. Nanjing high and low temperature heat chamber structure Description: This device made of high quality materials, the use of domestic currently the most advanced processing equipment molding, shell surface spray, beautiful and smooth. Coordinate colors, angular design, smooth lines and natural. Liner imported high quality stainless steel, the rational design, durable. Equipment in conformity with the national standards, but also with practical and easy to control all aspects of performance are stable basis. In addition, the device has a easy to install, easy to operate. Nanjing high and low temperature heat chamber to meet the standards: ⒈ GB11158 ⒉ GB10589-89 technical conditions of high temperature chamber temperature chamber Technical conditions ⒊ GB10592-89 technical conditions of high and low temperature ⒋ GB / T10586-89 damp heat test chambers ⒌ GB /T2423.1-2001 temperature chamber test methods ⒍ GB / T2423.2-2001 temperature chamber test methods ⒎ GB / T2423.3-93 heat chamber test methods ⒏ GB / T2423.4-93 Damp heat test method change ⒐ GB / T2423.22-2001 temperature test methods ⒑ IEC60068-2-1.1990 temperature chamber test methods ⒒ IEC60068-2-2.1974 temperature chamber test methods ⒓ GJB150.3 high temperature and low temperature test test ⒔ GJB150.4 ⒕ GJB150.9 Humidity Test high and low temperature heat chamber (Unit: mm) :( W × H × D) Model: KW-TH-80 internal dimension: 400 × 500 × 400 Carton size: 970 × 1360 × 970 Model: KW-TH-150 internal dimension: 500 × 600 × 500 Carton size: 1070 × 1460 × 1070 Model: KW-TH-225 internal dimension: 500 × 750 × 600 Carton size: 1070 × 1610 × 1170 Model: KW-TH-408 internal dimension: 600 × 850 × 800 Carton size: 1170 × 1710 × 1280 Model: KW-TH-800 internal dimension: 1000 × 1000 × 800 Carton size: 1550 × 1850 × 1300 Model: KW-TH-1000 internal dimension: 1000 × 1000 × 1000 Carton size: 1550 × 1850 × 1500 volume: 80L 150L 225L 408L 800L 1000L temperature range: Z: 0 ~ 150 ℃ T: -20 ~ 150 ℃ F: - 40 ~ 150 ℃ S: -70 ~ 150 ℃ Humidity range: Standard: 20% to 98% (humidity in 5% to 98%) Temperature fluctuation: ± 0.5 ℃ Temperature uniformity: ± 2.0 ℃ Humidity fluctuation: ± 2% RH humidity uniformity: ± 2.5% RH heating rate: 1.0 ~ 3.0 ℃ / min cooling rate: 0.7 ~ 1.2 ℃ / min Power: 1ф3W 220V ± 10% or 3ф5W380V ± 10% Nanjing high and low temperature heat chamber control system: Cowan independent research KW-890 microcomputer temperature and humidity control one: big screen vivid color screen: TFT LCD (LED backlight) 7 inches TFT color VGA (800x480) II: interactive touch-screen input system, easy to operate easy to learn, powerful, and to understand and monitor the process of programmed curve of the LCD screen; Third: PV curve / group curve: real representation of temperature and humidity PV, SV graph showing the history of the stored curve, the curve representing the group and conduct like four: You can set program 120 group, section 1200, the number of cycles up to 999 times, each time the maximum set 99 hours 59 minutes; V: USB communication interface backup / history curve / historical data, easy to use; also Optional RS485 interface, RS232 communication interface, can easily control and monitoring via PC. Six: a procedural amendment, clear, appointments, start, power, memory, key lock function; seven: screen protector function, you can set the program to run when the operating conditions, a segment times running time (530 hours 59 minutes) each can be set to standby switch, setting maximum 999,999 hours; eight: a variety of alarm, fault occurs at the same time, through the fault display screen, eliminating fault; Nine: recording error history, provides users with access, full screen Available in English, Chinese language; ten: BMP file represents: via USB download history curve BMP image format files. Heating system: 1, the use of far-infrared heating Nichrome wire-speed electric heating; 2, high temperature, low temperature completely independent systems; 3, the temperature control using P I D + S S R co-channel coordinated control system; refrigeration???? System: 1, in order to ensure the chamber for cooling rate and the minimum temperature requirements, the chamber's refrigeration system cascade refrigeration system consisting of imported compressor, the refrigeration system has a reasonable match, high reliability and easy maintenance etc. 2, refrigeration works: a refrigeration cycle are used against the card if the loop, which consists of two isothermal and two adiabatic process, whose process is as follows: adiabatic compression of the refrigerant through the compressor to a higher pressure, consumed work so that the exhaust temperature, after which the refrigerant through the condenser and other places in and around the medium temperature heat exchange medium heat to four weeks. After the refrigerant flows through the shutoff valve adiabatic expansion work, when the refrigerant temperature decreases. Finally, the refrigerant passes through the evaporator isothermal heat from high temperature object, the object to be cooled so that the temperature is lowered. This cycle so as to achieve the purpose of cooling the cycle 3, design application refrigeration system energy regulation technology, an effective treatment can guarantee but also on energy and cooling capacity of the refrigeration system carried out under the normal operation of the refrigeration unit effective regulation, the refrigeration system operating costs down to a more economical status Nanjing high and low temperature heat chamber energy-efficient design: In addition to fully consider the safety of refrigeration units, high-efficiency use of all sectors, but while taking multiple energy saving measures : such as: refrigeration system cooling capacity adjustment, liquid-gas bypass regulation, evaporation temperature regulation, at any point of constant low temperatures, without heating balance, operating power can be reduced to half, so that operating costs and failure rates refrigeration system decreases to more economical status. Expansion of the use of intelligent automatic conversion system load automatically adjust the refrigerant flow + intelligent electric power data value (%) to match heating and cooling (load) Automatic analog output data output value based. This design than conventional designs can be saving more than 30%. Temperature control output by the microcomputer calculus, to achieve high precision and high efficiency power efficiency. Note: Be sure to choose the time according to their test needs refer to the following points: ⒈ temperature range: The temperature range of the number of devices, you can refer to the highest minimum temperature value ⒉ gentle cycle functions: whether the device has a temperature of circulation, namely: repeatedly to cycle between the temperature curve cycle. ⒊ humidity range: whether the device with humidity function ⒋ heat load: Many electronic product testing will be energized test, in the case of power, the product being tested may have a fever, this will lead to the load. So sometimes buy back the equipment, such as the standard is 20 degrees, but the temperature does not drop down to the last is for this reason, we must keep up with the manufacturer's instructions load. ⒌ handling equipment: Refer to the device's dimensions, location and equipment final arrangements cases, such as door size, dimensions and other stair lifts. ⒍ Power: Refer to device size laboratory electrical power is consistent with the final placement or satisfied. Nanjing high and low temperature heat chamber factory direct service: manufacturers provide free installation, commissioning and technical training and other services. Equipment machine free year warranty and lifetime maintenance. Technician during the warranty period free quarterly maintenance to improve the life of equipment and services for users to follow. |
Admin>>>
You are the 15660 visitor
Copyright © GuangDong ICP No. 10089450, Dongguan City Cowan test equipment company All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 15660 visitor
Copyright © GuangDong ICP No. 10089450, Dongguan City Cowan test equipment company All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility